SCI – Model 297
מאפיינים מרכזיים
5 kV @ 12 mA AC Hipot, 6 kV @ 5 mA DC Hipot with Insulation Resistance Tester, CE Listed
Our Model 297 is a simple-to-use Hipot Tester with the built-in ability to easily test Insulation Resistance and Ground Continuity (Low Current Continuity) in a one-box solution. The 297 is capable of performing Hipot Tests in both AC & DC currents. Make testing simple with common sense security settings. PLC Remote allows you to make Hipot Testing safer with Personal Protective Equipment (PPE). You need a Hipot Tester that includes all the features you need to get the job done, the 297 has what you're looking for.
Hipot עם יכולות בדיקה כדלקמן:
- AC Hipot
- DC Hipot
- Insulation Resistance
- Ground Continuity
INPUT (294, 295, 296, 297, 298) | |
Voltage | 100-120 VAC / 200-240 VAC ± 10% Auto Range |
Frequency | 50/60 Hz ± 5% |
Fuse | 3.15 A / 250 VAC Fast-Blow |
DIELECTRIC WITHSTAND TEST MODE | ||
Output Rating | 298 | AC 0-5.00 kVAC, 99.99 mA |
297 | AC 0-5.00 kVAC, 12.00 mA DC 0-6.00 kVDC, 5.00 mA |
|
296 | AC 0-5.00 kVAC, 12.00 mA DC 0-6.00 kVDC, 5.00 mA |
|
295 | AC 0-5.00 kVAC, 12.00 mA | |
294 | DC 0-6.00 kVDC, 5.00 mA | |
Voltage Setting | 298 297 296 295 |
0-5.00 kVAC Resolution: 0.01 kV Accuracy: ± (1.5% of setting + 5V) |
297 296 294 |
0-6.00 kVDC Resolution: 0.01 kV Accuracy: ± (1.5% of setting + 5V) |
|
Output Frequency | 294 | DC only |
295, 298 | 50/60 Hz Selectable | |
296, 297 | DC and 50/60 Hz Selectable | |
Accuracy | ± 0.1% | |
AC Waveform | Sine Wave, Crest Factor = 1.3 – 1.5 | |
DC Output Ripple | 294 296 297 |
<5% ( 6 kVDC / 5mA at Resistive Load) |
Dwell Timer | 0, 0.2 – 60 sec, (0=continuous), 0.1 sec/step | |
Ramp Timer | 0.2 – 180 sec, 0.1 sec/step | |
Leakage Failure Settings |
298 | AC Hi-Limit: 0.10 – 99.99 mA Lo-Limit: 0 – 99.99 mA |
Resolution: Accuracy: |
0.01 mA ± (2% of reading + 0.06 mA) |
|
297 296 |
AC Hi-Limit: 0.10 – 12.00 mA Lo-Limit: 0 – 12.00 mA DC Hi-Limit: 0.02 – 5.00 mA Lo-Limit: 0 – 5.00 mA |
|
295 | AC Hi-Limit: 0.10 – 12.00 mA Lo-Limit: 0 – 12.00 mA |
|
294 | DC Hi-Limit: 0.02 – 5.0 mA Lo-Limit: 0 – 5.00 mA |
|
Resolution: Accuracy: |
0.01 mA ± (2% of reading + 0.02 mA) |
|
Discharge Time | < 50 msec for no load, < 100 msec for capacitive load |
INSULATION RESISTANCE TEST MODE (297 only) | ||
Output Voltage | Range: Resolution: Accuracy: |
0.1-1.00 kVDC 0.01 kV ± (1.5% of setting + 3 V) |
Resistance Display | Range: Resolution: Accuracy: |
1 – 1000 MΩ 1 MΩ 100-499 V ± (7% of setting + 2 MΩ) 500-1000 V ± (3% of setting + 2 MΩ) |
Hi-Limit | Range: Resolution: |
0.1 – 1000 MΩ (0=off) 1 MΩ |
Lo-Limit | Range: Resolution: |
1 – 1000 MΩ 1 MΩ |
Timer | Ramp: Delay: |
0.1 or 2.0 sec 0, 0.5 – 999.9 sec, (0=continuous) |
GENERAL SPECIFICATIONS | ||
Continuity Feature | Range: Resolution: Accuracy: |
0.0 – 1.50 Ω 0.01 Ω ± (2% of setting + 0.02 Ω) |
Memories | 5 (10 optional) | |
Remote I/O | Input: Output: |
Test, Reset, Interlock Pass, Fail, Test-in-Process Hardware Interlock – a relay on the high voltage output opens when the Interlock signal is disabled. |
3mA AC/DC Current Limit (optional) |
294 295 296 297 |
Range: 0.00 – 3.00 mA Resolution: 0.01 mA Accuracy: ± (2% of setting + 0.02mA) |
Meter Max (standard) |
Displays the maximum voltage value recorded during a breakdown. | |
Imax (optional) |
Displays the maximum leakage current value read during a test. Option 3 (USB port) must be installed to receive this measurement. | |
Security | Option to turn On or Off, when On you can switch between two security levels: 1. Run – Operator can only run a test. No ability to change memory locations or edit test parameters. 2. Mem – Operator can run a test and change memory locations. No ability to edit test parameters. |
|
Safety Mark | CE/cTUVus | |
Dimensions (W x H x D) |
294, 295 296, 297 |
8.5" x 3.5" x 11.9" (215 x 88.1 x 300 mm) |
298 | 16.93" x 5.20" x 11.84" (430 x 132 x 300 mm) | |
Weight | 294, 295 296, 297 |
12 lbs (5.46 Kg) |
298 | 46 lbs (20.86 Kg) |
לקבלת מידע צור קשר
השאירו פרטיכם ונחזור אליכם