SCI – Model 295

מאפיינים מרכזיים

5 kV @ 12 mA AC Hipot Tester, CE Listed

Our Model 295 is a simple-to-use AC Hipot Tester with the built-in ability to test Ground Continuity (Low Current Continuity). You need a Hipot Tester that includes all the features you need to get the job done, the 296 has what you're looking for. Make testing simple with common sense security settings. PLC Remote allows you to make AC Hipot Testing safer with Personal Protective Equipment (PPE).

Hipot עם יכולות בדיקה כדלקמן:

  • AC Hipot
  • Ground Continuity

INPUT (294, 295, 296, 297, 298)

Voltage 100-120 VAC / 200-240 VAC ± 10% Auto Range
Frequency 50/60 Hz ± 5%
Fuse 3.15 A / 250 VAC Fast-Blow

 

DIELECTRIC WITHSTAND TEST MODE

Output Rating 298 AC 0-5.00 kVAC, 99.99 mA
297 AC 0-5.00 kVAC, 12.00 mA

DC 0-6.00 kVDC, 5.00 mA

296 AC 0-5.00 kVAC, 12.00 mA

DC 0-6.00 kVDC, 5.00 mA

295 AC 0-5.00 kVAC, 12.00 mA
294 DC 0-6.00 kVDC, 5.00 mA
Voltage Setting 298

297

296

295

0-5.00 kVAC

Resolution: 0.01 kV

Accuracy: ± (1.5% of setting + 5V)

297

296

294

0-6.00 kVDC

Resolution: 0.01 kV

Accuracy: ± (1.5% of setting + 5V)

Output Frequency 294 DC only
295, 298 50/60 Hz Selectable
296, 297 DC and 50/60 Hz Selectable
Accuracy ± 0.1%
AC Waveform Sine Wave, Crest Factor = 1.3 – 1.5
DC Output Ripple 294

296

297

<5% ( 6 kVDC / 5mA at Resistive Load)
Dwell Timer 0, 0.2 – 60 sec, (0=continuous), 0.1 sec/step
Ramp Timer 0.2 – 180 sec, 0.1 sec/step
Leakage Failure

Settings

298 AC Hi-Limit: 0.10 – 99.99 mA

Lo-Limit: 0 – 99.99 mA

Resolution:

Accuracy:

0.01 mA

± (2% of reading + 0.06 mA)

297

296

AC Hi-Limit: 0.10 – 12.00 mA

Lo-Limit: 0 – 12.00 mA

DC Hi-Limit: 0.02 – 5.00 mA

Lo-Limit: 0 – 5.00 mA

295 AC Hi-Limit: 0.10 – 12.00 mA

Lo-Limit: 0 – 12.00 mA

294 DC Hi-Limit: 0.02 – 5.0 mA

Lo-Limit: 0 – 5.00 mA

Resolution:

Accuracy:

0.01 mA

± (2% of reading + 0.02 mA)

Discharge Time < 50 msec for no load, < 100 msec for capacitive load

 

INSULATION RESISTANCE TEST MODE (297 only)

Output Voltage Range:

Resolution:

Accuracy:

0.1-1.00 kVDC

0.01 kV

± (1.5% of setting + 3 V)

Resistance Display Range:

Resolution:

Accuracy:

1 – 1000 MΩ

1 MΩ

100-499 V ± (7% of setting + 2 MΩ)

500-1000 V ± (3% of setting + 2 MΩ)

Hi-Limit Range:

Resolution:

0.1 – 1000 MΩ (0=off)

1 MΩ

Lo-Limit Range:

Resolution:

1 – 1000 MΩ

1 MΩ

Timer Ramp:

Delay:

0.1 or 2.0 sec

0, 0.5 – 999.9 sec, (0=continuous)

 

GENERAL SPECIFICATIONS

Continuity Feature Range:

Resolution:

Accuracy:

0.0 – 1.50 Ω

0.01 Ω

± (2% of setting + 0.02 Ω)

Memories 5 (10 optional)
Remote I/O Input:

Output:

Test, Reset, Interlock

Pass, Fail, Test-in-Process

Hardware Interlock – a relay on the high voltage output opens when the Interlock signal is disabled.

3mA AC/DC

Current Limit

(optional)

294

295

296

297

Range: 0.00 – 3.00 mA

Resolution: 0.01 mA

Accuracy: ± (2% of setting + 0.02mA)

Meter Max

(standard)

Displays the maximum voltage value recorded during a breakdown.
Imax

(optional)

Displays the maximum leakage current value read during a test. Option 3 (USB port) must be installed to receive this measurement.
Security Option to turn On or Off, when On you can switch between two security levels:

1. Run – Operator can only run a test. No ability to change memory locations or edit test parameters.

2. Mem – Operator can run a test and change memory locations. No ability to edit test parameters.

Safety Mark CE/cTUVus
Dimensions

(W x H x D)

294, 295

296, 297

8.5" x 3.5" x 11.9" (215 x 88.1 x 300 mm)
298 16.93" x 5.20" x 11.84" (430 x 132 x 300 mm)
Weight 294, 295

296, 297

12 lbs (5.46 Kg)
298 46 lbs (20.86 Kg)
לקבלת מידע צור קשר השאירו פרטיכם ונחזור אליכם