Associated Research's LINECHEK II Leakage Current Tester is designed for medical device manufacturers. With a feature set built around maximizing the efficiency of the Leakage Current test, LINECHEK II satisfies medical application requirements demanding up to 40 Amps of continuous line current. Use it on the bench or in a rack, from the front panel or via a PC interface to ensure your medical device is ready for global deployment. The LINECHEK II Series includes model 620L.

Test Capabilities

Leakage Current

Ensure your product’s leakage current remains at acceptable levels during 8 different fault conditions.

Functional Run

Verify that your product is working properly before shipment.

 

Benefits designed with you in mind

Active Link®

Maximize testing efficiency by maintaining continuous power to the device under test during a leakage current testing sequence.

Interconnection

Interconnect your LINECHEK II and OMNIA II Series to form a complete safety compliance system.

Modular Scanner

Increase throughput for your test environment by virtually adding an endless number of Hipot or Ground Bond test points with our SC6540 modular multiplexer. With 8 combinations to choose from for each SC6540 module, this scanner is the ideal solution for high throughput production with reduced operator error.

Remote Safety Interlock

Create a safe workstation by incorporating a DUT enclosure, light curtain, or other device into our Remote Safety Interlock circuit.

INPUT
Voltage 115/230 VAC ± 10%, User selection
Frequency 50/60 Hz ± 5%
Fuse 2A Slow-Blo 250V AC
LINE CONDITION
Reverse Power Switch Reverse polarity switch setting select ON/OFF/AUTO
ON: Reverse power
OFF: Normal
AUTO: Automatic Reverse Polarity. With AUTO mode, the polarity switches for normal conditions in one step setting menu but will run two steps for both conditions. In this mode, the unit only records and displays the maximum leakage current value.
Neutral Switch ON/OFF selection for single fault condition
Ground Switch ON/OFF selection for Class I single fault condition
PROBE SETTING
Surface to Surface (PH – PL)
Surface to Line (PH – L)
Ground to Line (G – L)
LEAKAGE LIMIT SETTING
Touch Current High Limit (RMS) Range: 0.0uA ~ 999.9uA
1000uA ~ 9999uA
10.00mA ~ 20.00mA
Resolution: 0.1uA / 1uA / 0.01mA
Touch Current Low Limit (RMS) Range: 0.0uA ~ 999.9uA
1000uA ~ 9999uA
10.00mA ~ 20.00mA
Resolution: 0.1uA/1uA/0.01mA
Touch Current High Limit (Peak) Range: 0.0uA – 999.9uA
1000uA – 9999uA
10.00mA – 30.00mA
Resolution: 0.1uA/1uA/0.01mA
Touch Current Low Limit (Peak) Range: 0.0uA – 999.9uA
1000uA – 9999uA
10.00mA – 30.00mA
Resolution: 0.1uA/1uA/0.01mA