Fluke – TS® 54 TDR Test Set

מאפיינים מרכזיים

A three-in-one—TDR, toner and pair identifier—premium, VDV telephone test set..

Ten testing functions include:

  • TDR – find cable length measurement and locate faults on virtually all types of cable including twisted pair, coaxial, and parallel conductors
  • Toner – five separate tones for fast and easy differentiation between multiple wire pairs
  • SmartTone® – short the correct pair and tone changes for exact pair identification
  • Data indication – warns when data is present on the line
  • Voltage indication/measurement – identifies potential line problems
  • Current (mA) indication/measurement – verifies sufficient line current
  • Caller-ID with Call Waiting CID – verifies functional service
  • DTMF Digit Grabbing – isolates faulty customer premise equipment
  • Detects dial tone, places and receives calls
  • Polarity

Ten Testing Functions Include:

  • TDR – find cable length measurement and locate faults on virtually all types of cable including twisted pair, coaxial, and parallel conductors
  • Toner – five separate tones for fast and easy differentiation between multiple wire pairs
  • SmartTone® – short the correct pair and tone changes for exact pair identification
  • Data indication – warns when data is present on the line
  • Voltage indication/measurement – identifies potential line problems
  • Current (mA) indication/measurement – verifies sufficient line current
  • Caller-ID with Call Waiting CID – verifies functional service
  • DTMF Digit Grabbing – isolates faulty customer premise equipment
  • Detects dial tone, places and receives calls
  • Polarity

 

Additional Features:

  • DropSafe™ PRO – passed 20-foot drop test onto concrete
  • RainSafe™ PRO – protection for extreme weather conditions
  • DataSafe™ PRO – prevents disruption of data transmission on the line
  • High-visibility keypad with glow-in-the-dark keys for any outside plant environment
  • Extra-large, backlit LCD screen
  • Familiar, cell phone-like menu and user interface
  • Two-way, hands-free speakerphone
  • Optional headset

Electrical

Current range (Off-hook) 10 mA to 100 mA

DC Resistance

Off-hook 150 Ω nominal
On-hook >3 M Ω

AC Impedance

Off-hook 600 Ω nominal; 300 Hz to 3400 Hz
On-hook >120 kΩ 300 Hz to 3400 Hz
Headset impedance 32 Ω

Rotary Dial Output

Pulsing Rate 10 pps ±1 pps
Break/make ratio 60/40
Interdigit interval >300 ms
Resistance during break >100 kΩ

DTMF Output

Tone frequency error ±1.5 % maximum
Tone Level -3 dBm combined (typical)
High versus low tone difference 2 dB ± 2 dB

Speed Dialing

Memory capacity 9 speed dial memoriesof 23 digits, plus one last number redial memory
PBX pause duration User programmable; default of 4 seconds
Hook flash duration User programmable; default of 500 ms
Automatic shut-off duration User programmable; default of 2 minutes

Voltage measurement

Range 4 V dc to 140 V dc

Current measurement

Range 0 mA to 100 mA

TDR

Range 3,000 feet (914 m)
Accuracy ±2 m ±5 %

SmartTone toner

Frequencies Steady tone: 950 Hz
Power
Battery type 9 V alkaline battery

Physical

Measurement 8.3 in x 3.2 in x 2.6 in (211 mm x 81 mm x 66 mm) (without belt)
Weight 1.16 lb (0.53 kg) (without belt clip)
Water resistance The test set is rain and moisture resistant and IP64 rated

Environmental Temperature Range

Handset speech and dialing functions -22°F to 140 °F (-30°C to 60°C)
LCD function -13°F to 140°F (-25°C to 60°C)
Storage -22°F to 150°F (-30°C to 66°C)
Altitude To 10,000 ft. (3,000 m) max
Relative Humidity 95% to 30°C
75% to 40°C
45% to 50°C
30% to 60°C

Safety

Regulatory compliance Complies with ANSI/ISA 82.02.01 (61010-1) 2004, CAN/CSA-C22.2 No 61010-1-04, UL 61010-1 (2004) and IEC 61010-1:2010 for measurement category I, 300 V dc maximum, pollution degree 2
Maximum transient voltage 1500 V
EMC Complies with EMC EN61326-1

 

Note: Specifications subject to change without notice.

לקבלת מידע צור קשר השאירו פרטיכם ונחזור אליכם