Fluke – TS® 100 PRO Cable Fault Finder w/ PowerBT™ Bridge Tap

מאפיינים מרכזיים

Bridge tap detection at the touch of a button.

 

  • Reports distance to multiple bridge taps up to 3,200 feet (975 metres)
  • Tests opens and shorts up to 8,000 feet (2.4 kilometres)
  • Patented SmartTone for exact pair identification
  • Built-in TDR and toner
  • AC/DC voltage detection
  • One-button testing

Features:

  • Bridge tap detection for  xDSL pre-qualification
    • Reports distance to multiple bridge taps up to 3,200 feet (975 metres)
    • Sees past bridge taps to the end of the cable
  • Long-distance tester—tests opens and shorts up to 8,000 feet (2.4 kilometres)
  • Patented SmartTone tone generator with five different tones for exact pair identification
  • Built-in TDR (Time Domain Reflector)
  • AC/DC voltage detection
  • One-button testing
  • Built-in toner

 

Benefits:

  • Affordable bridge tap detection
  • Improve xDSL network performance
  • Five-in-one tool—distance to bridge taps, open  and short circuits, voltage detector and SmartTone with five different tones
  • No complicated set up or expertise required
  • No interpretation or analyses of complex graphs
Maximum Length 8,000 feet (2,438 meters) on certain cable types, 4,000 feet (1,220 meters) on most cable types, and 500 feet (152 meters) on cables with high loss. The tester shows -Err if the cable is too long to be correctly measured.
Representative Maximum Cable Length 8,000 feet (2,438 meters): CAT-3 Twisted Pair
8,000 feet (2,438 meters): CAT-5 Twisted Pair
6,000 feet (1,830 meters): 12/2 AC Wire
3,000 feet (900 meters): RG-6/U TV Coax
1,500 feet (457 meters): RG-174/U Coax
Minimum Length No minimum length (can read a bridge tap at 0 feet/meters). Minimum non-zero reading is 2 feet or 1 meter.
Length Accuracy ±2 feet (±0.6 m) for cables less than 10 feet (3 m)
±5 feet (±2 m) for cables longer than 10 feet (3 m) and shorter than 200 feet (60 m)
+/-3%+/-5 feet (±2 m) for cables longer than 200 feet (60 m)
Distance to Bridge Tap 0 feet to 3,200 feet (975 meters)
Minimum Length of Bridge Tap 10% of the distance to the bridge tap. Dependent on the cable characteristics.
Measurement Rate Maximum of 4 complete measurements per second, decreasing to 2 seconds per measurement based on cable size and uniformity.
VOP Adjustable from 20 to 99, saved in flash memory.
Test Technology Time Domain Reflectometry (TDR) with 100 Ω drive impedance, 6v maximum pulse height.
Cable Type Virtually all two or more conductor cables.
Power 4 AA alkaline batteries.
Reverse Battery Protection No damage to the tester will occur if the batteries are installed backwards.
Battery Life 35 hours (typical)
Low Battery Indication LED display alternates between LO and bAtt when the battery voltage falls below 4.5v.
Maximum Output Voltage 4 voltage peak
Maximum Isolation Voltage 250 volts RMS
Voltage Measurements Range: 0 volts AC to 115 volts AC; 0 volts DC to ±150 volts DC
Accuracy: AC: +/-1%+/-2 volts (45 Hz to 65 Hz); DC: +/-1%+/-2 volts DC
High Voltage Detection AC voltage detected to 115 volts; DC voltage detected to ±150 volts.
AC voltage ≥90 volts or DC voltage ≥100 volts causes high voltage warnings to show on the display
SmartTone® (5-tones) Range 7,000 feet (2,134 meters)
Toner Range 52,800 feet (16,093 meters)
Tone Injection Approximately 1 kHz at an amplitude of 80% of battery voltage. Variable frequency and cadence. Tone characteristics change as cable condition changes to “normal-open” from any other condition.
Impedance Range 35 Ω to 330 Ω with auto-compensation within this range. Cables with impedances outside this range will not be properly tested and may produce erratic or incorrect readings.
Temperature Range Operating: 32°F to 104°F (0°C to 40°C)
Storage: 32°F to 131°F (0°C to 55°C)
Humidity Operating: 20% to 80% relative humidity
Storage: 0% to 100% relative humidity
Operating Humidity 80% maximum at 86°F (30°C )
50% maximum at 104°F (40°C )
Operating Altitude 9,843 ft max (3,000 m max)
Weight 1 lb (454 grams)
Dimensions 7.4 in x 2.7 in x 1.4 in (18.8 cm x 6.9 cm x 3.6 cm)
Safety IEC 61010-1:2010; N10140
EMC: IEC/EN61326-1:2006
Certifications and Compliance  Conforms to relevant European Union directives
 Conforms to relevant Australian standards
 IEC/EN61010-1 CAN/CSA-C22.2 No. 1010.1-92 + CSA-C22.2 No. 1010.1B-97, UL/ANSI 3111-1

 

 

Notes: Patents 6160405, 6285195, 6323654, and 6509740. Specifications subject to change without notice.

לקבלת מידע צור קשר השאירו פרטיכם ונחזור אליכם