Fluke – 5502A Multi-Product Calibrator

מאפיינים מרכזיים

The 5502A Multi-Product Calibrator replaces the 5500A and addresses common workload items like 3.5 and 4.5 digit digital multimeters and more. It comes with internal and external protection features that enable you to transport it easily and perform onsite or mobile calibration. The 5502A can also be fully automated with MET/CAL® Plus Calibration Management Software. It is the ideal calibrator for metrology professionals who need a solution for calibrating low-to-medium accuracy electrical instrumentation.

Robust, transportable solution to match your workload and budget

  • Calibrates a wide variety of electrical test equipment
  • Robust protection circuits prevent costly damage from operator error
  • Ergonomically designed carrying handles make the 5502A easy to transport
  • Rugged carrying case with built-in handles and wheels and removable front/rear access doors for in-situ calibration in almost any environment
  • Current output that extends to 120 A when paired with the 52120A Transconductance Amplifier
  • Remarkably affordable

 

The 5502A calibrator covers many of the most common items in your workload, including:

  • Handheld and bench meters (analog and digital) to 4.5 digits
  • Current clamps and clamp meters
  • Panel meters
  • Electronic thermometers
  • Chart recorders
  • Oscilloscope recorders
  • XY recorders
  • Data loggers

Summary Specifications

Function & range
Direct volts 0 to ± 1020 V
Direct current 0 to 20.5 A
Alternating volts 1 mV to 1020 V
10 Hz to 500 kHz
Volt*Hertz 1000 V@ 10 kHz/330 V@100 kHz
Alternating current 29 μA to 20.5 A
10 Hz to 30 kHz
Waveforms Sine, square, triangle, truncated sine
Resistance 0 Ω to 1100 MΩ
Capacitance 220 pF to 110 mF
Power (phantom loads) 20.9 kW
Phase control 0.01°
Thermocouple (source and measure temperature) B, C, E, J, K L N R, S, T, U
10 μV/°C and 1 mV/degC
RTD (source temperature) Pt 385-100 Ω, Pt 3926-100 Ω Pt 3916-100 Ω,
Pt 385-200 Ω, Pt 385-500 Ω, Pt385 1000 Ω,
PtNi 385-120 Ω, (Ni120), Cu 427 10 Ω
Interfaces RS-232, IEEE 488
Frequency uncertainty <25 ppm
Calibration Documentation 17025 accredited report of calibration included
Oscilloscope calibrator (optional) Levelled sine wave from 5 mV to 5.5 Vpp max, frequencies 50 kHz to 600 kHz; edge rise times of < 300 ps, multiple trigger functions, lowest dc, square wave and timing uncertainty
Current boost transconductance amplifier 0 to 100 A dc, 0 to 120 A ac, dc to 10 kHz, up to 6000 A with accessory current coils
לקבלת מידע צור קשר השאירו פרטיכם ונחזור אליכם